With over three0 years of experience in heat pump design, production, and application, it has stood the test of time, ensuring high energy efficiency ratio and efficient dehumidification.
The testing equipment of Hefei General Machinery and Electrical Equipment Testing Institute, a national authoritative testing institution, has better indicators than national standards.
Dual compressor, dual fan design, high-quality refrigeration equipment and accessories. The operating modes are flexible and diverse, with high stability to meet the different needs of users.
Aluminum alloy frame, double-layer painted copper plate embedded with PU, box structure design, which is both sturdy and durable, and greatly reduces operating noise and heat loss.
The application of two characteristic patents, Patent No. of Multifunctional Heat Pump with Evaporator Stable Operation Function: ZLtwo009twoone059ninety.7, and Patent No. of Multifunctional Heat Pump with Idle Refrigerant Recycling Function: ZLtwo009two0one59587.5, ensures the progressiveness of the equipment and adapts to the climate difference between the north and the south.
The titanium alloy pool water heat exchanger meets the corrosion resistance requirements of chloride ion water in CJJonetwotwo-two0one7 "Technical Code for Swimming Pool Water Supply and Drainage Engineering".
Adopting a finned coil with copper tubes threaded through aluminum sheets to ensure high heat transfer performance and low airflow resistance. Spray epoxy resin layer on the overall coil fins to prevent corrosion of the coil fins by chlorine containing air.
Adopting the Kale self-control system, intelligent program design, and fully automatic operation of the equipment to reduce human operational errors; Touchscreen panel with powerful security protection, control, and communication functions, bilingual in Chinese and English, and LCD display.
Multiple product series can be customized with non-standard twofour0kg dehumidification equipment to meet customers' multi-level needs.
| Model | VeP-025-TE | VeP-030-TE | VeP-040-TE | VeP-050-TE | VeP-060-TE |
| Total heat output kW | 48.1 | 59.8 | 79.8 | 96.2 | 116.8 |
| Total cooling output kW | 40.0 | 49.0 | 66.0 | 80.0 | 96.0 |
| Dehumidification capacity (return air 28 ℃, sixty%) kg/hr | 25.0 | 32.0 | 42.0 | 50.0 | 61.0 |
| Dehumidification capacity (return air29 ℃, sixty%) kg/hr | 26.5 | 34.0 | 44.5 | 53.0 | 65.0 |
| Dehumidification capacity (return air 28 ℃, 65%) kg/hr | 28.0 | 36.0 | 46.0 | 56.0 | 67.0 |
| Type of fan | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) |
| Specification, power * W * quantity of air supply fan | 4.2*1 | 4.2*1 | 4.2*1 | 4.2*1 | 4.6*1 |
| Air supply volume (variable frequency air supply) m ³/hr | 6000 | 7500 | 8500 | 10000 | 12500 |
| Maximum external residual pressure of the air supply fan (Pa) | 1560 | 1350 | 1150 | 950 | 750 |
| Exhaust air volume m ³/hr | 1200 | 1500 | 1700 | 2000 | 2500 |
| Maximum static pressure of exhaust (Pa) | 1340 | 1330 | 1320 | 1270 | 1120 |
| three00Pa static pressure maximum exhaust air volume m ³/hr | 3650 | 3650 | 3650 | 3650 | 3650 |
| Exhaust fan nameplate power kW | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Types of compressors | Fixed frequency scroll type (optional variable frequency scroll type) | Fixed frequency scroll type (optional variable frequency scroll type) | Fixed frequency scroll type (optional variable frequency scroll type) | Fixed frequency scroll type (optional variable frequency scroll type) | Fixed frequency scroll type (optional variable frequency scroll type) |
| Total number of compressors (unit) | 1 | 1 | 1 | 2 | 2 |
| Compressor power kW | 8.1 | 10.4 | 13.8 | 16.2 | 20.8 |
| Number and diameter of outdoor unit exhaust pipes | 1*7/8 | 1*7/8 | 2*7/8 | 2*7/8 | 2*7/8 |
| Quantity and diameter of return copper pipes for outdoor units | 1*5/8 | 1*5/8 | 2*5/8 | 2*5/8 | 2*5/8 |
| Refrigerant | R-four10A (R-407C customizable) | R-410A (R-407C customizable) | R-410A (R-407C customizable) | R-410A (R-407C customizable) | R-410A (R-407C customizable) |
| Pool water heat exchanger | titanium alloy | titanium alloy | titanium alloy | titanium alloy | titanium alloy |
| Water resistance Mpa | 0.06 | 0.06 | 0.06 | 0.06 | 0.06 |
| Standard working pressure resistance Mpa | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 |
| Water flow rate m ³/hr | 8.3 | 10.3 | 13.8 | 16.6 | 20.1 |
| Water pipe fitting size PVC | 63 | 63 | 90 | 90 | 90 |
| Power supply threeeightyV/3Ph/50Hz △ A | 35 | 45 | 60 | 70 | 80 |
| Reference size of heat pump mm | 2990*1370*1245 | 3200*1570*1245 | 3515*1570*1345 | 3515*1670*1445 | 3515*1770*1545 |
| Reference weight of standard unit kg | 1300 | 1500 | 1700 | 1900 | 2300 |
Remarks:
The standard operating conditions of the equipment are inlet water temperature of 28 ° C, return air dry bulb temperature of 29 ° C, and relative humidity of 60% RH.
Optional air supply function above dew point (i.e. both compressor and air-cooled condenser are equipped with variable frequency). If there is insufficient cold or heat, auxiliary cooling and heating equipment such as surface coolers can be designed and configured.
Targeted design and production can be carried out according to customers' requirements for wind pressure, air volume, air outlet direction, operation control orientation, auxiliary heating method, and heat dissipation method.
The host can be designed and produced according to special size requirements.
| Parameter item | VeP-080-TE | VeP-100-TE | VeP-120-TE | VeP-160-TE | VeP-200-TE | VeP-240-TE |
| Total heat output kW | 149.0 | 194.4 | 228.8 | 292.0 | 350.0 | 468.0 |
| Total cooling output kW | 123.0 | 162.0 | 188.0 | 242.0 | 288.0 | 386.0 |
| Dehumidification capacity (return air 28 ℃, 60%) kg/hr | 80.0 | 100.0 | 120.0 | 160.0 | 200.0 | 240.0 |
| Dehumidification capacity (return air 29 ℃, 60%) kg/hr | 85.0 | 106.0 | 127.0 | 168.0 | 214.0 | 255.0 |
| Dehumidification capacity (return air 28 ℃, 65%) kg/hr | 87.0 | 110.0 | 130.0 | 172.0 | 222.0 | 266.0 |
| Type of fan | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) |
| Specification, power * kW * quantity of air supply fan | 4.6*1 | 4.2*2 | 4.6*2 | 4.6*2 | 4.6*3 | 4.6*3 |
| Air supply volume (variable frequency air supply) m ³/hr | 16000 | 20000 | 24000 | 31000 | 37500 | 44000 |
| Maximum external residual pressure of the air supply fan (Pa) | 600 | 950 | 700 | 600 | 700 | 650 |
| Exhaust air volume m ³/hr | 3200 | 4000 | 4800 | 6200 | 8000 | 9000 |
| Maximum static pressure of exhaust (Pa) | 1530 | 1530 | 1040 | 980 | 1620 | 1440 |
| 300Pa static pressure maximum exhaust air volume m ³/hr | 3650 | 5900 | 5900 | 14300 | 14300 | 14300 |
| Exhaust fan nameplate power kW | 1.0 | 2.4 | 2.4 | 4.2 | 4.2 | 4.2 |
| Types of compressors | Fixed frequency scroll type (optional variable frequency scroll type) | Fixed frequency scroll type (optional variable frequency scroll type) | Fixed frequency scroll type (optional variable frequency scroll type) | Fixed frequency scroll type (optional variable frequency scroll type) | Fixed frequency scroll type (optional variable frequency scroll type) | Fixed frequency scroll type (optional variable frequency scroll type) |
| Total number of compressors (unit) | 2 | 2 | 2 | 3 | 3 | 4 |
| Compressor power kW | 26.0 | 32.4 | 40.8 | 48.6 | 61.2 | 81.6 |
| Number and diameter of outdoor unit exhaust pipes | 2*7/8 | 2*1-1/8 | 2*1-1/8 | 3*1-1/8 | 3*1-1/8 | 4*1-1/8 |
| Quantity and diameter of return copper pipes for outdoor units | 2*5/8 | 2*7/8 | 2*7/8 | 3*7/8 | 3*7/8 | 4*7/8 |
| Refrigerant | R-410A (R-407C customizable) | R-410A (R-407C customizable) | R-410A (R-407C customizable) | R-410A (R-407C customizable) | R-410A (R-407C customizable) | R-410A (R-407C customizable) |
| Pool water heat exchanger | titanium alloy | titanium alloy | titanium alloy | titanium alloy | titanium alloy | titanium alloy |
| Water resistance Mpa | 0.06 | 0.06 | 0.06 | 0.06 | 0.06 | 0.06 |
| Standard working pressure resistance Mpa | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 |
| Water flow rate m ³/hr | 25.7 | 33.5 | 39.5 | 50.4 | 59.2 | 79.2 |
| Water pipe fitting size PVC | 90 | 110 | 110 | 110+90 | 110+90 | 110×2 |
| Power supply (3eightyV/3P/50Hz) A | 100 | 120 | 150 | 180 | 220 | 280 |
| Reference size of heat pump mm | 3750*1870*1648 | 4500*2070*1848 | 4880*2210*2146 | 5000*2500*2300 | 5400*2700*2580 | 6000*2700*2870 |
| Reference weight of standard heat pump kg | 2800 | 3200 | 3900 | 4300 | 4600 | 5200 |
Remarks:
The standard operating conditions of the equipment are inlet water temperature of 28 ° C, return air dry bulb temperature of 29 ° C, and relative humidity of 60% RH.
Optional air supply function above dew point (i.e. both compressor and air-cooled condenser are equipped with variable frequency). If there is insufficient cold or heat, auxiliary cooling and heating equipment such as surface coolers can be designed and configured.
Targeted design and production can be carried out according to customers' requirements for wind pressure, air volume, air outlet direction, operation control orientation, auxiliary heating method, and heat dissipation method.
The host can be designed and produced according to special size requirements.
| Model | VeP-050-AE | VeP-060-AE | VeP-080-AE | VeP-100-AE |
| Maximum cooling capacity kW | 77.5 | 97.5 | 111.5 | 133.5 |
| Maximum heat capacity (kW) | 88.3 | 111.3 | 127.7 | 153.7 |
| Heat recovery from dehumidification and heat removal in kW | 59.8 | 79.8 | 96.2 | 116.8 |
| Direct heating capacity kW | 28.5 | 31.5 | 31.5 | 37.5 |
| Winter dehumidification capacity (return air 28 ℃, 60%) kg/hr | 32.0 | 42.0 | 50.0 | 61.0 |
| Summer dehumidification capacity (return air 28 ℃, 60%) kg/hr | 48.0 | 63.0 | 75.0 | 92.0 |
| Winter dehumidification capacity (return air 28 ℃, 65%) kg/hr | 36.0 | 46.0 | 56.0 | 67.0 |
| Summer dehumidification capacity (return air 28 ℃, 65%) kg/hr | 54.0 | 66.0 | 80.0 | 100.0 |
| Type of fan | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) |
| Power kW * Quantity on the nameplate of the air supply fan | 4.6*1 | 4.6*1 | 4.6*1 | 4.2*2 |
| Supply air volume m ³/hr | 11500 | 12500 | 15000 | 18500 |
| Maximum external residual pressure of the air supply fan (Pa) | 850 | 850 | 700 | 1200 |
| Exhaust air volume m ³/hr | 2300 | 2500 | 2000 | 3700 |
| Maximum static pressure of exhaust (Pa) | 1170 | 1120 | 850 | 1000 |
| 300Pa static pressure maximum exhaust air volume m ³/hr | 3650 | 3650 | 3650 | 3650 |
| Exhaust fan nameplate power kW | 1.0 | 1.0 | 1.0 | 1.0 |
| Refrigerant | R-410A | R-410A | R-410A | R-410A |
| Pool water heat exchanger | titanium alloy | titanium alloy | titanium alloy | titanium alloy |
| Water resistance MPa | 0.06 | 0.06 | 0.06 | 0.06 |
| Standard working pressure resistance MPa | 0.8 | 0.8 | 0.8 | 0.8 |
| Water flow rate m ³/hr | 10.3 | 13.8 | 16.6 | 20.1 |
| Water pipe connection size DE | 63 | 90 | 90 | 90 |
| Indoor heat pump power supply (380V/3P/50Hz) A | 45.0 | 60.0 | 70.0 | 80.0 |
| Outdoor heat pump power supply (380V/3P/50Hz) A | 22.0 | 24.0 | 24.0 | 31.0 |
| Outdoor heat pump model | RH-25-AE | RH-28-AE | RH-28-AE | RH-34-AE |
| Reference size of outdoor heat pump mm | 1102*448*1570 | 1102*448*1570 | 1102*448*1570 | 1102*448*1570 |
| Reference weight of outdoor heat pump kg | 143 | 143 | 143 | 150 |
| External condenser parameters | Please refer to the RC series external condenser section for details on size and weight | Please refer to the RC series external condenser section for details on size and weight | Please refer to the RC series external condenser section for details on size and weight | Please refer to the RC series external condenser section for details on size and weight |
| Indoor heat pump reference size mm | 3560*1570*1950 | 3850*1720*1950 | 3850*1870*1820 | 4200*2020*2220 |
| Reference weight of indoor heat pump kg | 1950 | 2210 | 2470 | 2990 |
Remarks:
The standard operating conditions of the equipment are inlet water temperature of 28 ° C, return air dry bulb temperature of 29 ° C, and relative humidity of 60% RH.
Direct heating conditions: outdoor dry wet bulb temperature is 7/6 ° C; return air dry wet bulb temperature is 28/22 ° C.
Optional variable frequency compressor, with the option to provide air supply above dew point.
| Model | VeP-130-AE | VeP-160-AE | VeP-200-AE | VeP-260-AE |
| Maximum cooling capacity kW | 171.5 | 221.5 | 259.5 | 325.5 |
| Maximum heat capacity (kW) | 197.5 | 253.9 | 300.3 | 375.5 |
| Heat recovery from dehumidification and heat removal in kW | 149.0 | 194.4 | 228.8 | 292.0 |
| Direct heating capacity kW | 48.5 | 59.5 | 71.5 | 83.5 |
| Winter dehumidification capacity (return air 28 ℃, 60%) kg/hr | 80.0 | 100.0 | 120.0 | 160.0 |
| Summer dehumidification capacity (return air 28 ℃, 60%) kg/hr | 120.0 | 150.0 | 180.0 | 240.0 |
| Winter dehumidification capacity (return air 28 ℃, 65%) kg/hr | 87.0 | 110.0 | 130.0 | 172.0 |
| Summer dehumidification capacity (return air 28 ℃, 65%) kg/hr | 130.0 | 165.0 | 195.0 | 258.0 |
| Type of fan | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) | EC centrifugal fan (permanent magnet frequency converter) |
| Power kW * Quantity on the nameplate of the air supply fan | 4.6*2 | 4.6*2 | 4.6*3 | 4.2*3 |
| Supply air volume m ³/hr | 24000 | 30000 | 36000 | 46000 |
| Maximum external residual pressure of the air supply fan (Pa) | 800 | 700 | 800 | 650 |
| Exhaust air volume m ³/hr | 4800 | 6000 | 7200 | 9200 |
| Maximum static pressure of exhaust (Pa) | 1040 | 1000 | 1700 | 1400 |
| 300Pa static pressure maximum exhaust air volume m ³/hr | 5900 | 14300 | 14300 | 14300 |
| Exhaust fan nameplate power kW | 2.4 | 4.2 | 4.2 | 4.2 |
| Refrigerant | R-410A | R-410A | R-410A | R-410A |
| Pool water heat exchanger | titanium alloy | titanium alloy | titanium alloy | titanium alloy |
| Water resistance MPa | 0.06 | 0.06 | 0.06 | 0.06 |
| Standard working pressure resistance MPa | 0.8 | 0.8 | 0.8 | 0.8 |
| Water flow rate m ³/hr | 25.7 | 33.5 | 39.5 | 50.4 |
| Water pipe connection size DE | 90 | 110 | 110 | 110 |
| Indoor heat pump power supply (380V/3P/50Hz) A | 100.0 | 120.0 | 150.0 | 180.0 |
| Outdoor heat pump power supply (380V/3P/50Hz) A | 36.0 | 54.0 | 62.0 | 72.0 |
| Outdoor heat pump Model | RH-40-AE | RH-56-AE | RH-68-AE | RH-80-AE |
| Reference size of outdoor heat pump mm | 1102*448*1570 | 1452*519*1738 | 1100*1150*2100 | 1100*1150*2260 |
| Reference weight of outdoor heat pump kg | 157 | 275 | 430 | 450 |
| External condenser parameters | Please refer to the RC series external condenser section for details on size and weight | Please refer to the RC series external condenser section for details on size and weight | Please refer to the RC series external condenser section for details on size and weight | Please refer to the RC series external condenser section for details on size and weight |
| Indoor heat pump reference size mm | 4770*2020*2270 | 5080*2120*2680 | 5420*2300*2720 | 5000*2650*2980 |
| Reference weight of indoor heat pump kg | 3640 | 4160 | 5070 | 5590 |
Remarks:
The standard operating conditions of the equipment are inlet water temperature of 28 ° C, return air dry bulb temperature of 29 ° C, and relative humidity of 60% RH.
Direct heating conditions: outdoor dry wet bulb temperature is 7/6 ° C; return air dry wet bulb temperature is 28/22 ° C.
Optional variable frequency compressor, with the option to provide air supply above dew point.
Working hours: 9:00-18:00
Contact Us: